Maintenance and repair plan for exported medical oxygen generators

Classification: Industry News

Release time: 2021-11-15

Summary: Medical oxygen export has transitioned from the past era of bottled oxygen to today's era of oxygen concentrator central oxygen supply in hospitals, significantly improving hospital work efficiency and enhancing the stability, convenience, controllability, and safety of oxygen supply. This significantly improves the overall competitiveness of hospitals. Let's take a look at the maintenance and repair plan for exported medical oxygen concentrators!

  With the rapid development of China's economy, people's living standards have continuously improved, competition in various industries has intensified, and patient service requirements have become increasingly high. Hospitals, as an important part of economic development, and their medical conditions and service levels are important standards for measuring the hospital's General Strength. Medical oxygen is one of the important gas sources in the emergency treatment and rehabilitation process of patients, directly affecting medical safety. In order to improve the medical conditions and service levels of hospitals, hospitals have successively introduced medical oxygen generators. Therefore, the export of medical oxygen has entered the era of central oxygen supply from oxygen cylinders in the past, greatly improving the efficiency of hospital work, improving the stability, convenience, controllability, and safety of oxygen supply, and greatly improving the overall competitiveness of hospitals. So, let's learn more aboutExport Medical Oxygen GeneratorsMaintenance and Repair Plan!

ds3nRHsOQL-UPJGdivf5lg.jpg

  Export Medical Oxygen GeneratorsMaintenance Introduction In daily work, the "maintenance" and "maintenance" of oxygen-generating equipment are two completely different concepts;

  Export medical oxygen generator repair refers to repairing the machine after a fault occurs in a certain part and the equipment breaks down. However, this often causes unexpected stagnation in the equipment. However, the repaired equipment will inevitably have subsequent consistency problems.

  For example, a certain oxygen-generating equipment burned out the compressor motor, but a single repair only needs to replace the winding of the new motor coil, and then directly restart the motor. However, there is no proactive in-depth inspection of indirect problems in the motor failure factors, such as whether the motor damage is caused by the following problems.

  1. Is it caused by aging electrical faults, loose wiring, poor contact, excessive current fluctuations, and the motor protection system being unable to function properly?

  2) Is it due to insufficient lubrication of the bearing balls and the wear and tear of the bearings, resulting in damage to the bearing housing?

  3. Avoid oil-gas separation cylinder core blockage leading to excessive motor load and long-term high-temperature operation causing fatigue damage.

  Therefore, due to the neglect of maintenance awareness during maintenance, in the operation of many companies' equipment, the "chronic disease" operation mode of repairing things often occurs, directly resulting in a decrease in the oxygen generator's pressure capacity, shortened lifespan, reduced operational reliability, and increased safety factor,

  Export medical oxygen generator maintenance is a superficial view—it refers to the maintenance of equipment in daily work. Some people often say "three divisions, seven divisions." Maintenance refers to timely and scientific fault diagnosis and maintenance according to the various performance characteristics of mechanical equipment during the daily, weekly, monthly, and annual maintenance cycles. This can prevent small problems early, eliminate major faults early, effectively reduce energy consumption, and provide safe and reliable guarantees.

  Export Medical Oxygen GeneratorsAdvanced performance technology, high degree of automation, all key components have SUPERVISOR monitoring and alarms, indicating faults and maintenance of oil filters, temperature control valves, oil-gas separation tanks, etc. Oil filter maintenance:

  Practice has proved that if the pressure difference before and after the oil filter exceeds 1.4 Bar, do not wait for the display to show a signal before performing maintenance, but perform maintenance after the running time exceeds 1000 hours or 5-6 months, and replace the new oil filter.

  Temperature control valve maintenance:

  When a temperature error is found, after inspection and Confirm, remove the pipe connected to the valve body, remove the four bolts connecting the upper and lower valve bodies, remove the gasket, remove the temperature control component, add oil to the replaced seal, put it into the valve body, and press the temperature control component into the valve body, sealing ring and upper part.

  The above is an introduction toExport Medical Oxygen GeneratorsMaintenance and repair plan. For more information, please Contact Us!

Key words: Maintenance and repair plan for exported medical oxygen generators